一、初始化SysTick
按1ms来设置systick,也可以除以1000000。按1us来设置
SysTick_Config(SystemCoreClock / 1000); //SysTick开启系统tick定时器并初始化其中断,1ms
二、systick的函数
// cycles per microsecond static volatile uint32_t usTicks
= 0
; // current uptime
for 1kHz systick timer
. will rollover after 49 days
. hopefully we won
't care
. volatile uint32_t sysTickUptime
= 0
; // SysTick void SysTick_Handler
(void
) { sysTickUptime
++; } //delay ms void DelayMs
(uint16_t nms
) { uint32_t t0
=micros
(); while(micros
() - t0
< nms
* 1000
); } // Return system uptime
in microseconds
(rollover
in 70minutes
) //返回 us uint32_t micros
(void
) { register uint32_t ms
, cycle_cnt
; do { ms
= sysTickUptime
; cycle_cnt
= SysTick
->VAL
; } while (ms
!= sysTickUptime
); return
(ms
* 1000
) + (usTicks
* 1000
- cycle_cnt
) / usTicks
; } // Return system uptime
in milliseconds
(rollover
in 49 days
) uint32_t millis
(void
) { return sysTickUptime
; }
systick启动后会进入SysTick_Handler()的中断,
三、少了重要的一部,哭~T.T
开启RCC时钟!!!!!
void cycleCounterInit(void) { RCC_ClocksTypeDef clocks
; RCC_GetClocksFreq
(&clocks
); usTicks
= clocks
.SYSCLK_Frequency
/ 1000000
; }
遇到的错误:我在初始化MPU6050时,写入数据特别慢。明明计时都准的,不知道为什么特别慢。其他还都能顺利运行。
最后发现时RCC的时钟有问题。
<script>window._bd_share_config={"common":{"bdSnsKey":{},"bdText":"","bdMini":"2","bdMiniList":false,"bdPic":"","bdStyle":"0","bdSize":"16"},"share":{}};with(document)0[(getElementsByTagName('head')[0]||body).appendChild(createElement('script')).src='http://bdimg.share.baidu.com/static/api/js/share.js?v=89860593.js?cdnversion='+~(-new Date()/36e5)];</script>